doi: 10.52899/24141437_2026_03_357
UDK: 621.396.962
Improving the Accuracy of Coordinate Measurements of a Multi-Position Passive Meter for Continuous Radiation Sources
Самаров Е. К.
Article language: русский
Citation Link: Самаров Е.К. Повышение точности измерения координат многопозиционного пассивного измерителя источников непрерывного излучения // Труды
Санкт-Петербургского государственного морского технического университета. 2026. Т. 5, № 3. С. 357–363. DOI: 10.52899/24141437_2026_03_357
EDN: MAXLHD
Annotation
BACKGROUND: Correlation processing of signals in a passive multi-position meter is based on the fact that the cross-correlation
function is recovered from the received signal realizations at different positions according to the primary parameter—delay—
and the current measurement of the primary parameter—the signal arrival time delay relative to the reference—is determined
from the position of its maximum on the delay axis. For signals with a wide spectrum, the width of the main lobe of the crosscorrelation function is small, and it is not difficult to perform this measurement within the required accuracy. For signals with
a narrow spectrum, the width of the main lobe of the cross-correlation function becomes so wide that accurately measuring
delay readings becomes very difficult. Additionally, with limited accumulation time, the potential accuracy of correlation
measurements for signals with a narrow spectrum decreases. All these factors make the use of correlation meters challenging
for narrow-spectrum signals and make the problem pressing.
AIM: To improve the accuracy of coordinate measurements of a multi-position passive meter for continuous radiation sources
by means of correlation processing of narrow-spectrum signals with unknown parameters.
METHODS: A method is used for improving the accuracy characteristics of passive multi-position meters when receiving
narrow-spectrum signals, based on transforming the original signal spectrum to narrow the main lobe of the autocorrelation
or cross-correlation function of the received signal.
RESULTS: The considered method reduces the root-mean-square error in determining the location of a narrow-spectrum
signal source by more than 10 dB.
CONCLUSION: The considered method for improving the accuracy characteristics of passive multi-position meters when
receiving narrow-spectrum signals, based on transforming the original signal spectrum in order to narrow the main lobe
of the autocorrelation or cross-correlation function of the received signal, can be successfully applied in the design of passive
multi-position measurement systems.
Keywords: correlation signal processing; multi-position coordinate meter; narrow-spectrum signals.
Bibliography
1. Kondratyev VS, Kotov AF, Markov LN. Multiposition radio engineering
systems. Moscow: Radio i svyaz; 1986. 264 p. (In Russ.)
2. Anoshkin IM. Foreign multiposition radar systems for covert airspace
surveillance. Nauka i voennaya bezopasnost. 2007;(1):28–31. (In Russ.)
3. Davenport PB. Using multistatic passive radar for realtime detection
of UFO’s in the nearearth environment. Seattle: National UFO Reporting
Center; 2004. 16 p.
4. Bamak J, Baker G, Cunningham AM, et al. Silent sentry passive
surveillance. Aviat Week Space Technol. 1999;12.
5. Karshakevich D. The phenomenon of the “Pole” radar. Army.
2005;(1):32–33. (In Russ.)
6. Artyushenko VM, Volovach VI. Quasi-optimal signal processing
with the background of narrow band correlated non-gaussian noise.
Radioengineering. 2016;(7):125–132. EDN: WMHLKH
7. Artyushenko VM, Volovach VI. Measuring the parameters of motion
of extended objects in conditions interferences and change range. Dual
Technologies. 2015;(1):69–74. EDN: TJUXQR